Refrigeration control system compressor failure caused by oil pressure
If there is no oil pressure in the refrigeration control system, check the oil pump piping system connection for oil leakage or blockage. If the connection is loose, the joint should be tightened. If it is blocked, the oil pipeline should be cleared. Then check whether the compressor of the refrigeration control system is too large due to the opening of the oil pressure regulating valve or the valve core is detached. If the hydraulic pressure regulating valve of the refrigeration control system is improperly adjusted, adjust the oil pressure regulating valve and adjust the oil pressure to the required value. If the valve core is detached, the valve core should be reinstalled and tightened. If there is too little oil in the crankcase of the refrigeration control system or there is refrigerant, the oil pump will not enter the oil. If the oil is too small, it should be timely. Refueling, if it is the latter, stop in time to eliminate the refrigerant. Pay attention to the oil pump. If the oil pump wears out seriously, the clearance will be too large, causing the oil pressure to not come up. In this case, the oil pump should be repaired and replaced directly if the fault is serious. The timely cooling control system checks whether the connecting rod bearing bush, the main bearing bush, the connecting rod small head bushing and the piston pin have been seriously worn, and the relevant parts are replaced in time, and the rear end cover gasket of the crankcase is misplaced, blocking the intake of the oil pump. The oil passage should be disassembled and the position of the gasket should be re-fixed.

Of course, the oil temperature of the refrigeration control system needs to be in the normal range. If the oil temperature is too high, it is necessary to check in time whether the shaft and the tile are improperly assembled, and the clearance is too small. The size of the shaft and tile assembly clearance should be adjusted so that the clearance meets the standard requirements. It is. Next, check the lubricating oil for impurities, which will cause the bearing bush to be pulled. For this, the brushed bushing should be flattened and replaced with new oil. If the tile is severely pulled, replace the new tile. Then check that the shaft seal friction ring is installed too tightly or the friction ring is pulled, and the shaft seal friction ring is re-adjusted in time. If the friction ring is severely pulled, replace the new friction ring. If the suction and exhaust temperatures of the compressor of the refrigeration control system are too high, the system’s liquid supply valve should be properly adjusted to restore the suction and exhaust temperatures to normal.
Overall, the refrigeration control system compressor failure solution is not as simple as imagined, so we need our operators to know more about our refrigeration control system and have enough knowledge to face these faults.
Recommandations connexes
-
Manufacturer explains what are the influences of the oil level and oil difference of the chiller?
1185The chiller manufacturer tells everyone that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil reservoir and special oil cooler. Therefore, we must understand the influence of the oil l...
Voir les détails -
Causes and troubleshooting of low-temperature water chillers for photoetching machines
915The operator of the low-temperature chiller for lithography machine can have a certain understanding of the related faults and solutions during the operation of the equipment, so as to better use the low-temperature chiller for lithography machine...
Voir les détails -
Comment tester les composants du régulateur de température de la puce à l'aide d'un multimètre ?
1215Le dispositif de contrôle de la température des puces est utilisé dans des composants tels que les puces, les semi-conducteurs et les circuits intégrés. Comment utiliser un multimètre pour ces composants courants ? Transformateurs, bobines de déviation, inductances de compensation, etc. de c...
Voir les détails -
La coopération avec les plus forts ! La cérémonie de signature de la coopération stratégique entre LNEYA et Siemens s'est achevée avec succès
2640Le 25 mai 2021, la cérémonie de signature de la coopération stratégique entre LNEYA Constant Temperature Refrigeration Technology Co., Ltd. et Siemens (China) Co., Ltd. s'est tenue à Wuxi, en Chine. Lors de la cérémonie de signature, des dirigeants tels que Que Yaoyao, direc...
Voir les détails