Pourquoi les machines d'emballage et de triage des semi-conducteurs doivent-elles utiliser des refroidisseurs ?
In the semiconductor packaging testing process, especially in the temperature control process of the sorting machine (test probe station), the use of chillers is mainly based on the following reasons:
Temperature stability and accuracy: The performance testing of semiconductor devices is extremely sensitive to temperature. Subtle temperature fluctuations will affect the accuracy of test results and the performance evaluation of the device. The chiller provides a stable low-temperature environment to ensure minimal temperature fluctuations during the test process, ensuring the repeatability and accuracy of test data.
Thermal management: During the test process, especially high-power devices will generate a large amount of heat energy when running. The chiller can effectively take away this heat energy to prevent heat accumulation, keep the test equipment and DUT at a safe operating temperature, and avoid thermal stress damage to the equipment. Or affect the test accuracy.
Améliorer l'efficacité : The rapid cooling of the chiller can shorten the time for the device to cool to the test temperature and improve the test efficiency. Especially when multiple temperature cycle tests or rapid temperature changes are required, the efficiency of the chiller is more critical.
Protect devices: The chiller avoids large temperature fluctuations that may be caused by direct use of ambient temperature control, and protects sensitive semiconductor devices, especially new semiconductor materials or precision devices that are sensitive to temperature.
Environmental adaptability: The semiconductor testing environment requires constant temperature and humidity. The chiller is not affected by temperature changes in the external environment and can ensure a stable indoor testing environment even in extreme weather.
Extend the service life: By reasonably controlling the temperature, the chiller avoids overheating, expansion and contraction of the equipment, protects the equipment, and extends the service life of the test equipment.
In summary, the application of chillers in temperature control of semiconductor sealing, testing and sorting machines is a key technical means to ensure test accuracy, efficiency, protect equipment, improve product quality and environmental adaptability, and extend equipment life.
Semiconductor Cooling Chillers
FLT-100℃~90℃
Refroidisseur à air à canal unique, principalement conçu pour les machines de gravure. Il est utilisé pour assurer un contrôle indépendant de la température des parois latérales de la chambre.
FLTZ -45℃~90℃
La méthode de chauffage à 40 ℃ adopte un compresseur de chauffage à gaz chaud entièrement fermé, et la machine fonctionne en continu pendant 24 heures Le dispositif de contrôle de la température à semi-conducteur Le refroidisseur est principalement utilisé pour p...
chargement...
已经是到最后一篇内容了!
Recommandations connexes
-
Does the chip lead bonding process require a temperature control system?
871The chip lead bonding process indeed requires precise temperature control, so temperature control systems are usually equipped to ensure process stability and yield. The following are the importance and application scenarios of temperature con...
Voir les détails -
FLT -45℃~40℃
1898Modèle FLT-402 FLT-402W FLT-403 FLT-403W FLT-404 FLT-404W FLT-406 FLT-406W FLT-408 FLT-408W FLT-410 FLT-410W FLT-415 FLT-415W Contrôle de la température -45℃~40℃ Précision du contrôle de la température ±0.1℃ Contrôle du débit 10~25L/min 5bar max 15~45L/m...
Voir les détails -
Refroidisseurs de semi-conducteurs pour le test des puces
417Semiconductor chillers ensure precise temperature control in chip testing, improving reliability, reducing failures, and protecting wafer quality.
Voir les détails -
Comment fonctionnent les refroidisseurs CVD et PVD pour semi-conducteurs ?
1071Le principe de fonctionnement des refroidisseurs utilisés dans les processus de dépôt chimique en phase vapeur (CVD) et de dépôt physique en phase vapeur (PVD) des semi-conducteurs consiste principalement à éliminer la chaleur générée pendant le processus en faisant circuler de l'eau de refroidissement ou des...
Voir les détails