KRYZ Frequency conversion series
- Capacité de refroidissement0.5kW~10kW
- Capacité de chauffage0.5kW~10kW
- RéfrigérantR134A/R1234yf
- Poids115KG~300KG
Air-cooling & Water-cooling
Détails de la configuration
Modèle | KRYZ-475 KRYZ-475W |
KRYZ-4A15W | KRYZ-4A25W | |
Plage de température | -40℃~+100℃ | |||
Précision du contrôle de la température | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
Retour d'information sur la température | Pt100 | Pt100 | Pt100 | |
Affichage de la température | 0.01k | 0.01k | 0.01k | |
Flow output | 1~25 L/min | 1~25 L/min | 1~25 L/min | |
About traffic description | When the temperature is below -30 degrees, the flow rate is controlled within 80% of the maximum value. | |||
Flow control accuracy | ±0.1 L/min | ±0.1 L/min | ±0.1 L/min | |
Affichage de la pression | Using pressure sensor, the pressure is displayed on the touch screen, and the pressure control can be adjusted from 0.2bar to 2.5bar | |||
Heating capacity kW | 7.5 | 15 | 25 | |
Cooling capacity kW | 100℃ | 7.5 | 15 | 25 |
20℃ | 7.5 | 15 | 25 | |
0℃ | 7.5 | 15 | 25 | |
-20℃ | 4.5 | 10 | 16 | |
-35℃ | 1.8 | 4 | 6.5 | |
Compresseur | Inverter scroll compressor | |||
Méthode d'étranglement | Soupape d'expansion électronique | |||
Séparateur d'huile | Emerson | |||
Filtre déshydrateur | Danfoss | |||
Évaporateur | Échangeur de chaleur à plaques | |||
Pompe de circulation | Variable frequency magnetic drive pump | |||
Entrée, affichage | 7-inch color touch screen, PLC controller | |||
Programming | 5 programs can be compiled, each program can compile 40 steps | |||
Communications | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet TCP/IP protocol | |||
Protection de la sécurité | It has self-diagnosis function; refrigerator overload protection; high pressure switch, overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection and other safety protection functions. | |||
Système | The entire system is a fully closed system. There will be no water vapor at high temperatures and no absorption of moisture in the air at low temperatures. The system will not cause pressure to rise due to high temperatures during operation, and will automatically replenish heat transfer media at low temperatures. | |||
Réfrigérant | R404A/ R507C | |||
Taille de l'interface | G3/4 | G3/4 | G3/4 | |
Water cooled @25℃ | 2500L/H ZG3/4 |
4000L/H ZG1 |
6000L/H DN32 |
|
Condenseur refroidi à l'eau | The water equipment condenser of this product adopts plate heat exchanger, which requires water supply from chiller or low hardness tap water, and requires water purification filter | |||
Air cooled condenser | Échangeur de chaleur à microcanaux | / | / | |
Power supply 380V50HZ | 14kW | 25kW | 38kW | |
Dimensions en cm | 55*85*175 | 70*100*175 | 80*120*185 | |
Poids | 280kg | 360 kg | 620kg | |
Standard | Automatic antifreeze filling system, automatic liquid recovery system | |||
En option | 220V 60HZ three-phase 400V 50HZ three-phase 440V 60HZ three-phase | |||
En option | Temperature extended to -40℃~+135℃ | |||
Remarque | The external circulation pipeline should have a diameter of DN15 or DN20. The pipeline needs to be well insulated, and high-temperature resistant rubber and plastic insulation pipes can be used. | |||
Matériau de la coque | Cold rolled sheet spraying (standard color 7035) |
Modèle | KRYZ-475W/2T | KRYZ-4A15W/2T | KRYZ-4A25W/2T | |
Plage de température | -40℃~+100℃ | |||
Précision du contrôle de la température | ±0.1℃ | ±0.1℃ | ±0.1℃ | |
Retour d'information sur la température | Pt100 | Pt100 | Pt100 | |
Affichage de la température | 0.01k | 0.01k | 0.01k | |
Flow output | 1~25 L/min | 1~25 L/min | 1~25 L/min | |
About traffic description | When the temperature is below -30 degrees, the flow rate is controlled within 80% of the maximum value. | |||
Flow control accuracy | ±0.1 L/min | ±0.1 L/min | ±0.1 L/min | |
Fluid output groups | 2 groups | 2 groups | 2 groups | |
Pressure control per group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
Flow Pressure Description | The device can control flow or pressure independently. Different solutions are required for simultaneous control (customization required) | |||
Heating capacity kW | 7.5*2 | 10*2 | 15*2 | |
Cooling capacity kW | 100℃ | 7.5*2 | 15*2 | 25*2 |
20℃ | 7.5*2 | 15*2 | 25*2 | |
0℃ | 7.5*2 | 15*2 | 25*2 | |
-20℃ | 4.5*2 | 8.5*2 | 14*2 | |
-35℃ | 1.8*2 | 4*2 | 6.5*2 | |
Compresseur | Inverter scroll compressor | |||
Méthode d'étranglement | Soupape d'expansion électronique | |||
Séparateur d'huile | Emerson | |||
Filtre déshydrateur | Danfoss | |||
Évaporateur | Échangeur de chaleur à plaques | |||
Pompe de circulation | Variable frequency magnetic drive pump | |||
Flow rate, pressure | Electromagnetic flowmeter, pressure value 4~20mA | |||
Entrée, affichage | 7-inch color touch screen, PLC controller | |||
Communications | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet TCP/IP protocol | |||
Protection de la sécurité | It has self-diagnosis function; refrigerator overload protection; high pressure switch, overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection and other safety protection functions. | |||
Système | The entire system is a fully closed system. There will be no water vapor at high temperatures and no absorption of moisture in the air at low temperatures. The system will not cause pressure to rise due to high temperatures during operation, and will automatically replenish heat transfer media at low temperatures. | |||
Réfrigérant | R404A/R507C/R125/N40 four refrigerants can be used | |||
External output interface size | There are 2 sets of inlet and outlet ports, G3/4 | |||
Water cooled @25℃ | 4000L/H ZG1 |
8000L/H DN32 |
12000L/H DN40 |
|
Condenseur refroidi à l'eau | The water equipment condenser of this product adopts plate heat exchanger, which requires water supply from chiller or low hardness tap water, and requires water purification filter | |||
Dimensions en cm | 80*120*185 | 100*150*185 | 200*145*205 | |
Power supply 380V50HZ | 28kW | 45kW | 70kW | |
Poids | 660KG | 850 kg | 1350kg | |
Standard | Automatic antifreeze filling system, automatic liquid recovery system | |||
En option | 220V 60HZ three-phase 460V 60HZ three-phase | |||
En option | Temperature extended to -40℃~+135℃ | |||
Remarque | The external circulation pipeline should have a diameter of DN15 or DN20. The pipeline needs to be well insulated, and high-temperature resistant rubber and plastic insulation pipes can be used. | |||
Matériau de la coque | Cold rolled sheet spraying (standard color 7035) |
1. Conditions nominales d'essai : température sèche 20℃ ; température humide 16℃. Température de l'eau d'entrée 20℃ ; température de l'eau de sortie 25℃.
2. Les données de ce tableau sont fournies à titre de référence uniquement. Veuillez vous référer aux paramètres de la plaque signalétique de l'appareil.
3. si vous avez besoin d'une personnalisation spéciale non standard, veuillez nous contacter.

Peut répondre aux besoins de refroidissement direct/chauffage direct pour les essais et les tests des batteries et des véhicules. Il est principalement utilisé pour tester la capacité de refroidissement et de chauffage. Il utilise un compresseur à fréquence variable dont la puissance est réglable et un ventilateur à fréquence variable dont la vitesse et la dissipation de chaleur sont réglables. Grâce à des capteurs de température, de pression et de débit de haute précision et à un logiciel intégré, il peut calculer la capacité d'échange thermique en temps réel, recycler et remplir automatiquement le réfrigérant, etc. Il peut répondre aux besoins de batteries de différentes tailles.
Ces produits peuvent également vous intéresser
Onduleur LTZ série M
APPLICATIONS Convient pour l'application à l'objet de régulation de la température cible qui dispose déjà d'un réservoir de stockage du froid et d'une pompe de circulation, et le fluide est transporté dans l'unité de régulation de la température de réfrigération de la série LTZ M par l'intermédiaire de l'unité de régulation de la température de réfrigération...
LN -60°C~ -10°C
适用范围 Caractéristiques du produit 产品参数 Paramètres du produit 行业应用 APPLICATION 航空航天材料|试验装置控温解决方案 在航空航天领域,材料的性能直接关系到飞行器的安全、可靠性和...
LT -80℃~-20℃
Il peut garantir un fonctionnement continu pendant 24 heures Réfrigération par circulation d'éthylène glycol mélangé à de l'eau 1. Peut utiliser de l'éthylène glycol mélangé à de l'eau pour la réfrigération par circulation, ce qui permet d'économiser les ressources....
chargement...
已经是到最后一篇内容了!