Recherche dans l'ensemble de la station


Centre d'information

Paramètres détaillés

KRY Unité Synbol 455/455W K475 4A10/4A10W 4A15/4A15W 4A25/4A25W 4A38W 4A60W
Plage de température  -40℃~+100℃
Sortie débit L/min 1~10 L/min 1~25 L/min 1~25 L/min 1~40 L/min 1~40 L/min 5~50 L/min 5~50L/min
Précision du débit  L/min ±0,2 L/min
Puissance de chauffage kW 5,5 kW 7,5 kW 10kW 10kW/Optionnel 15kW 15kW/Optionnel 25kW 25kW/Optionnel 38kW 38kW/Optionnel 60kW
Capacité de refroidissement 100℃ 5,5 kW 7,5 kW 10kW 15kW 25kW 38kW 60kW
200℃ 5,5 kW 7,5 kW 10kW 15kW 25kW 38kW 60kW
0℃ 5,5 kW 7,5 kW 10kW 15kW 25kW 38kW 60kW
 -35℃ 1,2 kW 1,8 kW 2,5 kW 4kW 6,5 kW 10kW 15kW
Réfrigérant   R404A/ R507C
Puissance 380V50HZ kW max 12kW max 15kW max 20kW max 29kW max 42kW max 58kW max 84kW max
Dimension(W) cm (W) cm 55*95*175 55*95*175 55*95*175 70*100*175 80*120*185 100*150*185 145*205*205
Dimension(A) cm (A) cm 55*95*175 55*95*175 70*100*175 80*120*185 100*150*185    

Poids (refroidissement par eau)

KG 250KG 280KG 320KG 360KG 620KG 890KG 1300KG
Mode de contrôle Feedback PID + notre calcul de contrôle dynamique spécial, contrôleur PLC
Contrôle de la température Modèle de contrôle de la température du processus et de la température de l'enveloppe
Différence de température Régler ou contrôler la différence de température entre l'huile de gaine et la matière première.
Éditeur de programmes 10 programmes, chaque programme peut éditer 40 étapes
Protocole de communication Protocole MODBUS RTU, interface RS485
Retour d'information sur la température du matériau PT100 OR 4~20mA ou communication(normale : PT100)
Retour d'information sur la température La température de trois points : l'entrée et la sortie de l'équipement, la température du matériau du réacteur (capteur de température externe).
Soupape d'expansion Détendeur thermique Emerson/détendeur thermique Danfoss
Évaporateur DANFOSS/KAORI Échangeur de chaleur à plaques
Panneau de commande Écran tactile de 7 pouces,Courbe de température affichéeEXCEL sortie de données
Protection de la sécurité Fonction d'autodiagnostic ; protection contre la surcharge du congélateur ; pressostat haute pression, relais de surcharge, dispositif de protection thermique, protection contre le niveau bas du liquide, protection contre les températures élevées et protection contre les défauts de température.
Système de circulation fermé L'ensemble du système est en circuit fermé, il n'y a pas de brouillard d'huile à haute température et pas de vapeur d'eau à basse température, la pression n'augmente pas lorsque le système fonctionne. Le système fournit automatiquement de l'huile à basse température.
Réfrigérant R404A/R507C/R125/N40  All four refrigerants are available

La plage de température est de -40℃~+100℃, qui peut être étendue à +135℃ en fonction de la situation réelle, et la précision de contrôle de la température est de plus ou moins 0,5℃. L'équipement peut contrôler le débit et la pression indépendamment tout en contrôlant la température, et différentes solutions personnalisées sont requises pour le contrôle simultané.


L'objet testé est fixé à un adaptateur de plate-forme de test.
L'intérieur de la pièce a été refroidi et chauffé par une solution aqueuse d'éthylène glycol.
Le composant testé doit passer par un profil de température spécifique et enregistrer les changements de température.
Les variations de température sont généralement comprises entre -40 ℃ et 100 ℃ (extensible à 150 ℃).
Lors d'un test de tolérance, une boucle infinie est généralement nécessaire.



此图片的 alt 属性为空;文件名为 03_1588131509-1.jpg

*
*

Multi-channel

Canal 1Canal 2Canal 3

Voltage

50HZ single phase50HZ three phase60HZ single phase60HZ three phase*
Soumission....
Envoyé avec succès !
Échec de la soumission ! Veuillez réessayer plus tard
Erreur d'email !
Erreur de téléphone !

Cooling Water Chiller:

  • Used to control the temperature of the battery pack to ensure that the battery pack can be kept within the specified temperature range during the test.
  • Can simulate the performance of the battery pack under different temperature conditions, such as low temperature start-up, high temperature operation, etc.

Heating System:

  • When it is necessary to simulate a high temperature environment, the heating system can be used in conjunction with the cooling water circulation machine to ensure that the battery pack can operate under high temperature conditions.

Environmental Simulation Chamber:

  • Provides a closed space for simulating different environmental conditions, such as temperature, humidity, air pressure, etc.
  • The interior of the environmental simulation box/chamber is usually equipped with monitoring equipment such as temperature sensors and humidity sensors, as well as control equipment such as heaters and humidifiers.

recommander des produits

  • KRY 0℃~+100℃ (1to2)"      /&gt;<figcaption><span>Temperature range is 0℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently …</span></figcaption></figure></a></div><div class=KRY 0℃~+100℃ (1to2)

    Temperature range is 0℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently …

  • KRY 0℃~+100℃ (1to3)"      /&gt;<figcaption><span>Test temperature of main test items of vehicle electronics: IC test conditions for locomotives: -40℃~125℃, wind blowing, sun exposure, high vibration; Instrument panel operation te…</span></figcaption></figure></a></div><div class=KRY 0℃~+100℃ (1to3)

    Test temperature of main test items of vehicle electronics: IC test conditions for locomotives: -40℃~125℃, wind blowing, sun exposure, high vibration; Instrument panel operation te…

  • KRY 0℃~+100℃(1&amp;6)"      /&gt;<figcaption><span>Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc. It can simulate the external environmental conditions in the climat…</span></figcaption></figure></a></div><div class=KRY 0℃~+100℃(1&6)

    Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc. It can simulate the external environmental conditions in the climat…

  • KRY 0℃~+100℃ (1to1)"      /&gt;<figcaption><span>La plage de température est de 0℃~+100℃, pouvant être étendue à +135℃ en fonction de la situation réelle, et la précision de contrôle de la température est de plus ou moins 0,5℃. L'équipement peut contrôler le débit et la pression indépendamment tout en...</span></figcaption></figure></a></div><div class=KRY 0℃~+100℃ (1to1)

    La plage de température est de 0℃~+100℃, pouvant être étendue à +135℃ en fonction de la situation réelle, et la précision de contrôle de la température est de plus ou moins 0,5℃. L'équipement peut contrôler le débit et la pression indépendamment tout en...

chargement...

已经是到最后一篇内容了!