How to Prolong the Service Life of Glycol Chiller System?

In order to extend the service life of your glycol chiller in industrial applications, please pay attention to the following points:
1. Use automobile grade antifreeze carefully
Do not use automobile grade or unqualified antifreeze. Because this glycol is not manufactured for industrial applications, it may cause a variety of problems and shorten the service life of your glycol chiller system.
2. Comply with local regulations.
Experts have designed different rules and regulations according to the environmental requirements of this specific area. These are called local regulations, which not only provide safe operation, but also prolong the service life of ethylene glycol chiller system for your industrial application.
3. Fluid filtration and equipment maintenance.
Another secret to prolong the service life of ethylene glycol chiller system is to use fluid filter and carry out fluid maintenance. Operate the equipment as specified in the manufacturer’s manual.
4. Perform all preventive and corrective maintenance.
All planned and unplanned maintenance must be performed to extend the service life of the glycol chiller system· Provide regular maintenance list for all users, such as cleaning, lubrication, dust removal and filter replacement. All inspections are completed in time according to the instructions in the manufacturer’s manual.
5. On time calibration of equipment.
Stickers are attached to all equipment requiring calibration. This shows the calibration date, all of which should be calibrated in time to improve the efficiency of the measuring instrument and prolong the service life of your glycol cooling system.
Recommandations connexes
-
La raison de l'alarme de haute pression de l'unité de contrôle de la température intégrée TCU
1011Lorsque l'unité de contrôle de la température intégrée TCU est utilisée, elle doit l'être conformément aux instructions détaillées. Lorsque des problèmes sont rencontrés, ils doivent être traités à temps. En règle générale, si nous rencontrons une alarme de haute pression de...
Voir les détails -
-45 °C freezer manufacturers analyze compressor burnout detection and repair methods
966In the -45 ° C freezer, the compressor is one of the more important components, the manufacturer Wuxi Guanya (LNEYA) tells everyone that once the compressor fails, it needs timely inspection and maintenance, then how to check the work and maintena...
Voir les détails -
After Adding A Backwater to the Heater, Hot Water Will Come Out Anytime and Anywhere in Winter
986The principle is also simple. A water pipe is added at the outlet of the hot water pipe to form a closed circuit. The recirculation pump is connected to the water heater. When the tap is turned on, the circulating pump automatically pumps the col...
Voir les détails -
Maintenance Method Of Ultra Low Temp Chiller Refrigeration System
1074The ultra low temp chiller refers to the refrigeration unit whose chilled water temperature reaches below minus 35℃. The unit adopts two-stage compression refrigeration, and the combination of the scroll compressor and the piston compressor is use...
Voir les détails