Précautions d'utilisation de l'équipement de contrôle de la température du réacteur de la série ZLF/SR
The temperature control equipment of the reaction kettle adopts the PID control method, which greatly improves the temperature control accuracy of the whole machine. The microcomputer for cooling or heating will automatically switch to work according to the temperature setting, which simplifies the operation procedure and avoids the damage to the machine due to misoperation.

1. The fully enclosed pipeline system reduces the oxidation of heat transfer oil and is equipped with a unique cooling function. The heat transfer oil will inevitably produce oil mist when it works at high temperature. If it is not cooled in time, its service life will be greatly shortened. With this cooling function not only prolongs the service life of the oil but also reduces the flow of circulating pressure.
2. At present, it is widely used in the pharmaceutical and chemical industry, and the specific size can be distinguished according to the model. Like general equipment, it also needs to be carefully maintained during use.
3. If it is not running, if only the cooling water tower is needed for cooling, it is necessary to turn off the water source for the temperature control of the TCU reactor, and dispose of the water in the internal components and pipes of the TCU reactor temperature control, and pay attention to avoid the temperature control of the TCU reactor. The residual liquid inside will corrode the internal components of the equipment. At the same time, you need to pay attention to the temperature of the equipment. Do not place it at too low temperature to avoid frost heaving copper pipes at low temperatures.
4. It is necessary to check whether each part inside the temperature control equipment of the reactor is worn or not. If any wear is found, please replace the parts in time. In addition, the fan of the reactor temperature control equipment should always be kept in a clean state to avoid dust blockage.
The above content is about the operation precautions of LNEYA’s TCU multi-reactor temperature control equipment. If you are interested and would like a quote, you can contact sales@lneya.com.
Recommandations connexes
-
Fully closed cycle high viscosity fluid refrigeration heating flow control system
941Application:1. The tested object is connected to a test platform adapter.2. The internal parts of the parts are cooled, heated, flow controlled, and pressure controlled by various lubricating oils, hydraulic oils, aviation fuel, fuel oil, and co...
Voir les détails -
Principle Analysis of Glycol Chiller
1112Glycol chiller is an industrial chillerwith glycol as refrigerant. The structure of glycol chiller is roughly the sameas that of ordinary industrial chiller, which is composed of compressor,evaporator, condenser and electric control system. ...
Voir les détails -
Precautions for use of minus 95 degrees cryogenic liquid bath cold trap
1085The minus 95 degree low temperature liquid bath cold trap (that is, the refrigerator that we often say) is a common refrigeration unit in refrigeration equipment. The rational use of the unit can not only avoid the failure of the unit, but also ma...
Voir les détails -
Quel est l'effet d'un petit refroidisseur à eau sur la production industrielle ?
1166Le petit refroidisseur à eau est utilisé dans un large éventail d'applications, telles que l'industrie alimentaire et l'industrie pharmaceutique. Dans certains domaines industriels, les petits refroidisseurs à eau sont souvent nécessaires. L'application de ...
Voir les détails