The Refrigeration Principle of Heating Cooling Circulator
Heating cooling circulator is the use of limited refrigerant in the closed refrigeration system, repeatedly refrigerant compression, condensation, expansion, evaporation, constantly in the evaporator heat absorption vaporization, cooling.
Le chauffage refroidissement circulateur is the circulation process that moves the heat from the low temperature object (such as the cold storage) to the high temperature object through the refrigerant, so as to cool the object below the ambient temperature and maintain the low temperature. This process is realized by the refrigeration device
The important parameter of the heating and cooling circulator is the coefficient of refrigeration, also known as the performance coefficient of the refrigeration unit, represented by the symbol COP. At a given ambient temperature, the lower the temperature of the cold storage, the smaller the coefficient of refrigeration.
The whole liquid cycle is closed, with the expansion vessel, the expansion vessel and the liquid cycle are insulated, do not participate in the liquid cycle, just mechanically connected, temperature the medium in the expansion vessel is less than 60 degrees no matter the liquid cycle temperature is high or low.
The whole liquid circulation is a closed system. At low temperature, there is no water vapor absorption, and at high temperature, there is no oil mist generation. Thermal oil has a wide range of operating temperature. No mechanical or electronic valves are used throughout the system.
Analysis of refrigeration principle
01.Compressed air refrigeration cycle
Due to the air constant temperature heating and constant temperature exhaust heat is not easy to achieve, so it can not run by the reverse cycle. In the compressed air refrigeration cycle, two constant pressure processes are used to replace the two constant temperature processes of the reverse cycle, so it can be regarded as the reverse cycle. In engineering applications, the compressor may be either piston or impeller type.
02.Compressed vapor refrigeration cycle
The reverse refrigeration cycle of compressed steam can be achieved in theory, but it will appear that the dry state is too low, which is not a positive factor for two-phase material compression. In order to avoid adverse factors, increase the refrigeration efficiency and simplify the equipment, in practical applications often use throttle valve (or expansion valve) to replace the expander.
Recommandations connexes
-
Maintenance of Glycol Cooling Heating Control System
1108Apart from the attention needed during the daily use, the regular check and maintenance of Glycol Cooling Heating Control System are also very important. In order to help all of you learn to use Glycol cooling heating more efficiently, Guanya Re...
Voir les détails -
How to deal with the malfunction of Industrial Water Chiller System?
1195What's wrong with the Industrial Water Chiller System when it fails to cool down? Let LNEYA explain it to you below: One reason is that the initial use of liquid chiller system fails to reduce the temperature, or there is something wrong with ...
Voir les détails -
Comment gérer l'alarme de défaillance de l'équipement du refroidisseur à recirculation ?
930Que faire en cas de panne et d'alarme pendant l'utilisation de l'équipement de refroidissement à recirculation ? Afin d'assurer la production, ces problèmes doivent être résolus rapidement. Nous devons d'abord comprendre les causes des pannes et des alarmes, et adopter dif...
Voir les détails -
Méthode d'inspection du dispositif d'essai environnemental des piles à combustible communes
1205Pendant le processus de refroidissement de l'appareil d'essai environnemental des piles à combustible, il est possible que des gouttes s'écoulent à l'intérieur. Il ne s'agit pas d'un phénomène normal utilisé par le dispositif d'essai environnemental des piles à combustible, mais d'une mauvaise installation. Après l'installation de la pile à combustible...
Voir les détails