LNEYA ultra-low temperature cold box power supply+electronic control instrument system description
LNEYA ultra-low temperature cold box needs to be tested after a long time of use. What should be paid attention to when the power supply and electronic control instrument system are inspecting?
LNEYA ultra-low temperature cold box power supply and electronic control instrument system inspection, before power-on should check whether the distribution capacity and unit power are consistent, whether the selected cable diameter can withstand the host operating current. Check whether the electrical system is consistent with the unit. The unit is electrically: three-phase five-wire system (three phase lines, one neutral line, one ground line, 380V ± 10%). Check if the power supply line of the compressor is connected tightly. If it is loose, retighten it. The torque at the compressor wiring is 500kg/cm. Due to factors such as long-distance transportation and lifting, the screws may be loose. Failure to do so may result in damage to electrical components (such as air switches, AC contactors, etc.) and compressors in the main control cabinet.
Use a multimeter to carefully inspect all electrical circuits of the LNEYA ultra-low temperature cold box, check that the wiring is properly installed in place; use megaohm measurement to make sure there is no short circuit in the case; check that the ground wire is properly installed in place, and the insulation resistance to ground is greater than 2MΩ; check if the power cable is Meet the capacity requirements. Check if the disconnect switch is installed on the power supply line of the supply unit. All the wiring of the main circuit in the control cabinet and the external wiring of the control circuit can be energized after comprehensive inspection (such as crankcase oil heater, compressor electronic protector, circulating water temperature sensor, target flow switch wiring, pump connection) Control, etc.); Check if the terminal bolts are tightened and there is no looseness.
The performance of the power supply and the electronic control instrument are more important in the operation of the LNEYA ultra-low temperature cold box, so it is necessary to check the recommendations regularly.

Recommandations connexes
-
Application pratique de différents compresseurs dans l'industrie du froid industriel
945In the current refrigeration industry, the efficiency of the equipment is closely related to temperature. LNEYA tells you that the efficiency of the refrigeration equipment required under control has been improved. Then, the selection of the compr...
Voir les détails -
How is the refrigerant installed in the vocs condensing unit?
1277The vocs condensing equipment is LNEYA's equipment for condensing adsorption of various vocs gases. Among them, the refrigerant of vocs condensing equipment is also indispensable. So, how should the refrigerant be treated? For various refrigeratio...
Voir les détails -
483Meet Your Dream Equipment for Distillate CBD Extraction
1273If you need equipment to distill CBD, you need to scrutinize your choices, as the equipment can vary in its features and design. When you use equipment that produces a CBD distillate, you want to seek out a system made by a manufacturer that provi...
Voir les détails -
Efficient method for extracting total cannabinoids using a cryogenic process cooling system
1204Although cannabis plants have been used for medicinal purposes for thousands of years, modern science has identified steroids, flavonoids and more than 100 therapeutically active compounds known as cannabinoids. Due to the significant synergy betw...
Voir les détails