Ion implantation is an important step in semiconductor manufacturing processes to precisely dope and control the electrical properties of semiconductor materials by implanting high-energy ions into them. This process generates a lot of heat, so chillers are needed to achieve the following goals. The temperature requirements of the chillers used in the ion implantation process are set according to the specific operating conditions of the ion implantation equipment and the characteristics of the semiconductor materials being processed. Although the specific temperature setting value may vary depending on the equipment model, process flow and the doping effect sought, in general, the chiller needs to be able to provide stable low-temperature cooling to maintain the temperature of key components in the ion implantation equipment within a precise and narrow range.

Temperature Range: The chiller is generally required to be able to provide cooling capacity from ambient temperature to approximately -20°C or even lower, depending on the heat generated during the ion implantation process and the cooling requirements of the equipment. For some high-end or special applications, lower temperature control capabilities may be required.
Temperature Stability: Temperature stability is extremely critical during the ion implantation process. The chiller needs to be able to maintain the set temperature fluctuation between ±0.1℃ and ±1℃ to ensure accurate control and repeatability of the implantation process.
Fast Response: The rapid temperature change during ion implantation requires the chiller to have a fast response capability, and to be able to quickly adjust the cooling output to adapt to changes in process requirements to avoid temperature exceeding the control range.
Cooling Uniformity: The chiller also needs to ensure that the temperature of the coolant is uniform during the circulation process to avoid local overcooling or overheating, which is very important for maintaining the consistency of the internal temperature of the equipment.
Intelligent Control: Modern ion implantation chillers are usually integrated with advanced temperature control and monitoring systems, such as PID controllers, which can automatically adjust the cooling output to respond to real-time temperature changes and ensure constant cooling effect.
In summary, the temperature requirements of ion implantation chillers in semiconductor manufacturing processes emphasize low temperature, high stability and fast response capabilities, aiming to create a highly controllable temperature environment for the ion implantation process, thereby ensuring the accuracy of doping and the performance of semiconductor devices.
SemiocnductorProcess Chillers
FLT-100℃~90℃
Refroidisseur à air à canal unique, principalement conçu pour les machines de gravure. Il est utilisé pour assurer un contrôle indépendant de la température des parois latérales de la chambre.
FLTZ -45℃~90℃
La méthode de chauffage à 40 ℃ adopte un compresseur de chauffage à gaz chaud entièrement fermé, et la machine fonctionne en continu pendant 24 heures Le dispositif de contrôle de la température à semi-conducteur Le refroidisseur est principalement utilisé pour p...
chargement...
已经是到最后一篇内容了!
Recommandations connexes
-
Pourquoi les tests de puces ont besoin de refroidisseurs de semi-conducteurs
412Struggling with chip test failures? See how semiconductor chillers keep wafers stable, cut downtime, and protect your production.
Voir les détails -
FLTZ -45℃~90℃
2525La méthode de chauffage à 40 ℃ adopte un compresseur de chauffage à gaz chaud entièrement fermé, et la machine fonctionne en continu pendant 24 heures Le dispositif de contrôle de la température à semi-conducteur Le refroidisseur est principalement utilisé pour p...
Voir les détails -
Série FLTZ multicanaux
2621La méthode de chauffage à 40 ℃ adopte un compresseur de chauffage à gaz chaud entièrement fermé, et la machine fonctionne en continu pendant 24 heures Principalement utilisée pour le contrôle précis de la température dans les produits semi-conducteurs.
Voir les détails -
Refroidisseurs de semi-conducteurs pour le test des puces
415Semiconductor chillers ensure precise temperature control in chip testing, improving reliability, reducing failures, and protecting wafer quality.
Voir les détails