Small coup to deal with ice blockage of high and low temperature liquid circulating chillers
In the operation of high and low temperature liquid circulating chillers, ice blockage is a relatively common fault. Based on the experience of relevant manufacturers, we have specially compiled relevant tips for dealing with ice jams.
In the pipeline of the high and low temperature liquid circulating chiller, if ice blockage occurs, it is recommended to replace the damaged pipe section and repair the missing spot welding first, and redo and tighten the loose threaded joint. In order to ensure that there is no leakage in the high-pressure test of the high and low temperature liquid circulating water chiller pipeline. The high and low temperature liquid cycle chiller refrigeration cycle system pipeline is divided into high pressure section and low pressure section, flushed with four-recording carbon, and purged with nitrogen to seal for later use.
At the same time, the high and low temperature liquid circulating chiller compressor unit must be strictly processed in accordance with the steps, replacing the new filter of the high and low temperature liquid circulating water chiller, and then blown and sealed for use. The high and low temperature liquid circulating chiller refrigeration cycle system pipeline is unsealed and the compressor unit is quickly assembled After that, perform quantitative charging of the refrigerant, and wait for five minutes (waiting for the static equilibrium of the pressure in the high-pressure zone and low-pressure zone in the refrigeration cycle system pipeline) to power on and test the machine.
When the user usually faces the operation of high and low temperature liquid circulating chillers, they need to pay attention to moisture prevention and seal or seal the parts of the high and low temperature liquid circulating water coolers that are not being repaired. Maintenance is carried out in rainy weather.
However, there is always a case in case. For high and low temperature liquid circulating chillers with slight ice blockage after maintenance, the refrigerant can be recovered, replaced with new filters, or connected in series with a large cubic freezer filter at the high-pressure exhaust end, or even Refill the refrigerant quantitatively.
There are one or two ways to face the phenomenon of ice blockage in high and low temperature liquid circulating chillers. If the user does not know how to solve it, do not solve it blindly by himself. It is recommended to find a professional maintenance person to solve it.
Recommandations connexes
-
Summary of Maintenance Items of Glycol Chiller
1114During the daily operation of glycol chiller, if the maintenance is not in place, the cooling effect of glycol chiller will be reduced. Therefore, in order to improve the operation efficiency of glycol chiller, we suggest that you should carry out...
Voir les détails -
Entretien et maintenance du refroidisseur de simulation de la température d'essai du bloc-batterie
909The battery pack test temperature simulation chiller is more and more widely used in enterprises, but the subsequent maintenance and maintenance are also more important. Here is a brief introduction to some maintenance and maintenance methods. 1....
Voir les détails -
Quel type de refroidisseur peut-on choisir pour refroidir la XRD ?
1091Quel type de refroidisseur pour le refroidissement de la XRD ?
Voir les détails -
What is the temperature control of the reactor?
1186The reactor cooling system is one of the common equipment in the chemical industry. It can not only heat but also refrigerate to meet the needs of heating and cooling in the reaction process. There are usually three ways to control the temperatu...
Voir les détails