Actualités

Function of Evaporator in Air Cooled Chiller
The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water quality, and saves water resources. It is the most economical and simple machine for maintenance and repair in the current refrigeration equipment. The one-time investment of air-cooled chiller is slightly higher than that of water-cooled chiller, but t...
Voir les détails
Introduction du thermostat à circulation pour le chauffage et la climatisation de LNEYA
Nowadays, the problem that plagues the pharmaceutical and chemical industry is the problem of temperature control. With the increasing industry demand and temperature control requirements of the pharmaceutical and chemical industry, the use of heating and cooling circulator thermostats is also increasing, showing an upward trend. In order to cope with the increasing domestic demand in the pharmaceutical and chemical industry, only constant innovation and optimization of the heating and coolin...
Voir les détails
Compressor key protection of reactor temperature control system
In the operation of the reactor temperature control system, the compressor is the core part, and its performance is more important. Therefore, it is necessary to protect the compressor. Under normal working conditions, the compressor of the temperature control system of the reactor should inhale the dry vapor of the refrigerant. There is also lubricating oil entering the cylinder. If there is too much liquid entering, it is too late to discharge from the exhaust valve, and the pressure in the...
Voir les détails
Précautions d'utilisation de l'équipement de contrôle de la température du réacteur de la série ZLF/SR
The temperature control equipment of the reaction kettle adopts the PID control method, which greatly improves the temperature control accuracy of the whole machine. The microcomputer for cooling or heating will automatically switch to work according to the temperature setting, which simplifies the operation procedure and avoids the damage to the machine due to misoperation. 1. The fully enclosed pipeline system reduces the oxidation of heat transfer oil and is equipped with a unique cooling...
Voir les détails
Comment éviter les erreurs opérationnelles dans les systèmes de régulation de la température par transfert de chaleur ?
During the operation of the fluid heat transfer temperature control system, if the fluid heat transfer temperature control system fails, the main reason is the operation error. So how do we avoid mistakes. 1. The operation of the fluid heat transfer temperature control system should pay attention to many aspects. First, operate the reactor strictly in accordance with the rules and regulations. Secondly, before operation, carefully check whether there is any abnormality. During normal operati...
Voir les détails
Details of the temperature control system of the isolated reactor
The temperature control system of the isolated reactor adopts the heat-conducting medium to perform dynamic temperature control of fluid cooling and heating, and to control the cooling and heating of the heat-conducting medium or the reaction material. If the material is controlled at high temperature and low temperature, it is necessary to pay attention when purchasing the temperature control system for the isolated reactor. What details and parameters? 1. The temperature range of the isolat...
Voir les détails
Introduction to mixed solution of glycol chilling systems (glycol chillers)
Glycol chillers are industrial refrigeration systems that use a type of antifreeze called glycol, mixed with water, to lower the freezing point in the application of the chilling system. Glycol is a class of organic compounds that belong to the alcohol family. When mixed with water and pumped through the pipes of a chilling system, glycol serves to slow the rate of freezing. It helps maintain temperature consistency in the application. Some glycol products also work to inhibit corrosion and...
Voir les détails
The importance of chiller compressors
In the operation of the precision chiller, the compressor is a more important part. If we want to understand the chiller, we have to understand the compressor. Most precision chiller compressors have a thermal switch inside. The function of this switch is to disconnect the power supply line to the motor of the compressor when the temperature of the compressor exceeds the set value, and it can be turned on until the compressor cools down. The compressor just works. This is the compressor's bui...
Voir les détails
Simulation du contrôle des variations de température dans le système de contrôle de la température de refroidissement et de chauffage de l'usine de production d'énergie de la région de la capitale du Canada.
Industrial cooling and heating temperature control system is a temperature control equipment used in the cooling and heating process of reaction kettle in the pharmaceutical and chemical industry. What are the characteristics of lneya's equipment? Industrial refrigeration heating temperature control system product application: 1. Temperature control of double-layer and three-layer reactors in chemical, pharmaceutical and biological fields; 2. Temperature control in material testing; 3. Temper...
Voir les détails
Model and size selection of cooling and heating circulator (pilot plant temperature control system)
The cooling and heating circulator adopts mechanical refrigeration, the low-temperature heating tube heats the high temperature, and the canned pump is used as the circulating pump. The liquid circulation of the whole system is closed and consists of two systems, each of which controls the corresponding system, and passes the heat transfer oil according to the process requirements. The cycle automatically adjusts heating or cooling. 1. The cooling and heating circulator consists of a pump, he...
Voir les détails